20 Sentences With "cable tray"

How to use cable tray in a sentence? Find typical usage patterns (collocations)/phrases/context for "cable tray" and check conjugation/comparative form for "cable tray". Mastering all the usages of "cable tray" from sentence examples published by news publications.

All requisite tools are included, and because the crossbars are pre-mounted to the desktop, all you really have to do is position the legs and secure them in place, attach the cables and the stability bar, and install the cable tray.
For petrochemical Industries the junction box or cable terminations require the junction box to be rated same or higher to that of the cable tray. Hence it cab be protected with the similar enclosure system used in Cable tray wrap enclosure as the objective is to keep the temperature on the electrical components below a critical temperature limit to be operable.
The NEC requires that conductors of a circuit must be inside a raceway, cable, trench, cord, or cable tray. Additional protection such as NM cable inside raceway is needed if the installation method is subjected to physical damage as determined by the authority having jurisdiction.
Using cable temperature as the failure criterion ensures that the maximum temperature at which functionality of any cable can be assumed to be maintained is not exceeded, even if circuit integrity can be maintained by the sample cable used in the fire test. Furthermore, the measurement of tray rather than cable temperature, with an empty tray, allows any cable loading to be used in practice. Importantly the cable tray is tested for structural stability which often is found to fail before the circuit integrity in Hydrocarbon fire cases. Hence cable enclosures ensures cable tray is tested along with cables and recommended as a better option.
Red cable ties made of ECTFE (Halar) are used for plenum cabling. Stainless steel cable ties are also available for flameproof applications—coated stainless ties are available to prevent galvanic attack from dissimilar metals (e.g. zinc-coated cable tray). PlastiCuffs are handcuffs based on the cable tie design and are used by law enforcement to restrain prisoners.
The exposed concrete slab was polished and used as the finish floor surface. The castellated steel beam structure, chosen for strength, lower cost, and reduced material was left exposed and painted white, allowing light, air and services to circulate. The metal cable tray system corrals electrical and data cabling also serve as the support for the light fixtures. Ceiling mounted acoustical panels double as light reflectors.
The construction features of an electrical room vary depending on the scope of the equipment to be installed. Floors may be reinforced to support heavy transformers and switchgear. Walls and ceilings may have to support a heavy cable tray system or busbars. Additional ventilation or air conditioning may be needed, since electrical apparatus gives off heat but the temperature must not rise beyond the tolerance of equipment.
The circuit is OK until it reaches the box. If the box is exposed to a fire, all the circuits connected to it become inoperable. Even if the electrical room that contains the box has a fire-resistance rating, this is a weak point because fires can break out in electrical rooms. Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another.
Supplement 1 is a particularly difficult and expensive test to pass. No testing is done in anything less than a full scale fire test, running easily into 6 figure costs per burn multiplied by all the applications one desires to test. In order to pass, one must test the smallest as well as the largest application (12" and 36" cable tray, 1/2" and 6" conduit). Accordingly, the approved materials are costly, as manufacturers must get a return on the large test investment.
For example, see cable tray movement in a German test. It is, therefore, important to test firestops in full scale wall panel tests, so that the deflection of each applicable assembly can be taken into account. The size of the test wall assembly alone is not the only consideration for firestop tests. If the penetrants are mounted to and hung off the drywall assembly itself during the test, this does not constitute a realistic deflection exposure insofar as the firestop is concerned.
Both mechanical and intumescent dampers form part of passive fire protection (PFP) systems, such as fire- resistance rated walls, floors, or even ducts or cable tray fireproofing. As such, they are PFP systems. However, whether an opening is mechanically closed or whether it is the physical/chemical action of an intumescent that does the work, the fact that they are activated by heat and then move to fulfill a fire safety function, also technically qualifies them to form part of active fire protection (AFP) systems.
Individual cables can exit the tray at any point, simplifying the wiring installation and reducing the labour cost for installing new cables. Power cables may have fittings in the tray to maintain clearance between the conductors, but small control wiring is often installed without any intentional spacing between cables. Local electrical regulations may restrict or place special requirements on mixing of voltage levels within one cable tray. Good design practices may segregate, for example, low level measurement or signal cables from trays carrying high power branch circuits, to prevent induction of noise into sensitive circuits.
ASTM E1725 uses cable tray temperature as the failure criterion because circuit integrity has been shown to be unreliable as an indicator of failure of a cable for hydrocarbon fires.This is the result of research that indicated cables believed to be of identical composition and rating had different functional failure temperatures. This means that circuit integrity failure cannot be assumed to reliably occur at the same time point in a fire. Therefore, it is more reliable to establish a maximum temperature beyond which any cable can be considered to be at risk of failure.
Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation. Successful tests in laboratories holding national accreditation for testing and certification result in the issuance of a certification listing. The listing is public domain, whereas the test report itself is proprietary information belonging to the test sponsor. There are many different types of fire tests apart from those on firestops.
Teck cables in industrial installation Teck cable is a very versatile power cable because it may be used where subject to limited mechanical damage, it is resistant to water, petrochemicals, and sunlight. It may be used for direct-earth burial and if properly sealed at the connection point, in explosive atmospheres such as gasoline dispensing stations. When used in industrial environment, it is usually contained in a cable tray with many other cables powering the motors that run the industrial processes. In the commercial environment, it may also be found in a tray, but is often fastened to a wall, truss, or other part of the building structure.
Where wiring, or raceways that hold the wiring, must traverse fire-resistance rated walls and floors, the openings are required by local building codes to be firestopped. In cases where safety- critical wiring must be kept operational during an accidental fire, fireproofing must be applied to maintain circuit integrity in a manner to comply with a product's certification listing. The nature and thickness of any passive fire protection materials used in conjunction with wiring and raceways has a quantifiable impact upon the ampacity derating, because the thermal insulation properties needed for fire resistance also inhibit air cooling of power conductors. A cable tray can be used in stores and dwellings Cable trays are used in industrial areas where many insulated cables are run together.
The Square Four coffee bar was wired with twin speakers in the ceiling, a home built amp, an outside broadcast socket for URE's totally unique "network" sockets. By 1989 a new coffee bar was mooted - the old Square 3 rooms: in a weekend long operation after the coffee bar was finished by estates, URE members put speakers over the ceiling tiles, and then ran a single screened cable under the podia (an operation involving a member walking 20 feet (6.3m) above the ground on a single cable tray), although the speakers were later cut into ceiling tiles, and then run through a single 100 volt transformer. The Square three coffee bar later closed, but in 2006 became what is now called Food on Three, still with the student radio station on speakers in the ceiling.
Thus, IPIP has fully designed the 11 oil refineries of Romania, totaling a processing capacity of about 40,000,000 Mt/y, and a great number of objectives abroad, spread worldwide and comprising, mainly, oil refineries, lube oil / gas processing complexes, oil terminal and other associated facilities.IPIP ReferencesGuwahati RefineryBarauni RefineryCentral Anatolia Refinery, Kirikkale IPIP SA has been audited and approved by Lloyd's Register Quality Assurance to the following Quality management System Standards: ISO 9001:2000, EN ISO 9001:2000, SR EN ISO 9001:2001, for Engineering, basic and detail design, project management, procurement, consultancy and technical assistance for oil refineries, gas processing and petrochemical plants, pipelines and related facilities. Design for indoor electrical systems for civil and industrial buildings, for 0.4 kV underground and above-ground branches. Design for 0.4-20 kV above-ground electrical lines or underground cable tray routing, and transformer substations.
Jett used the arm to grapple various pieces of hardware designed to hold large modular components, mimicking the way equipment boxes and avionics gear will be moved back and forth in assembling the Space Station. Chiao and Barry then unfolded a cable tray diagonally across the forward portion of the cargo bay housing simulated electrical and fluid lines similar to those which would later connect modules and nodes of the Space Station. The rigid umbilical, as it is known, was tested for its ease of handling and the ability of the astronauts to hook up the lines to connectors on the side of Endeavour's bay. While Chiao unraveled various lengths of cable from a caddy device, Barry spent time practicing the hookup of the various cables in the rigid umbilical to connectors in the bay, testing his ability to manipulate tiny bolts and screws in weightlessness.
The fire test should be carried out using a rapid rise hydrocarbon fire temperature/time curve such as ASTM 1529 or UL 1709 ( both considered functionally equivalent). The ASTM E1529 curve is slightly higher in temperature than UL 1709 and specifies a heat flux taken from measurements of hydrocarbon pool fires.The ASTM E1725-95 test method has stringent requirements for performance of cable tray fire insulation systems as opposed to the circuit integrity requirement assessed in BS 476 part 20 and DIN 4102, such as the test is run at positive pressure, thermocouples are fixed into the tray, test is intended to be run empty of cables ( worst case) , providing approval for 0% to 100% cable loading and failure is determined when one thermocouple ‘set’ reaches an average temperature rise of 250 °F, (121 °C) or any single thermocouple reaches 325 °F (163 °C).